A horizontal venturi meter with an inlet diameter of 20 cm and a throat diameter of 10 cm is used to measure the flow of oil of sp. gr. 0.8. The discharge of oil through the venturi meter is 60 liters/s. Find the reading of the oil-mercury differential manometer. Take Cd= 0.98.

 

FLUID MECHANICS
 

A horizontal venturi meter with an inlet diameter of 20 cm and a throat diameter of 10 cm is used to measure the flow of oil of sp. gr. 0.8. The discharge of oil through the venturi meter is 60 liters/s. Find the reading of the oil-mercury differential manometer. Take Cd= 0.98.

Verified Solution